Theremin Playability Lab
Is a short sensor range (say 30 cm for C2–C7) playable, and how accurate do the sensors need to be? Your pointer stands in for the hand. Every position runs through a hand model (arm sway + tremor), a sensor model (update rate, latency, noise, resolution) and the firmware's smoothing filter before it becomes pitch.
Sensor profileSpan and sensor settings are saved per profile
Ultrasonic · 30 cm strip · C2–C7Hold the mouse button (or touch) to play. Dashed line = your pointer, dot = what the sensor reports.
Move over the strip and hold the button to play.
5.00 mm per semitone (20.0 ¢/mm) · predicted wobble holding still 1.85 mm = 37¢ · must stay below 1.25 mm for ±25¢
Saved results
No tests yet. Results are kept in this browser; download the CSV to share them.
Sensor requirements
Simulates a perfectly aimed hand trying to hold one note for 20 s, using the current hand model, sensor rate, smoothing and tolerance. Each cell is the percent of time within ±25¢, with the 1σ wobble in brackets.